Muvia IndustrialField
Your machines talk. Muvia listens.
Drivers run on the node, read the variables you pick and turn them into named tags. Where the protocol allows it they can write too.
- Siemens S7Read and writeConnected
- OPC UASubscriptionConnected
- Modbus TCPReadWaiting for connection
Illustrative example
Field protocols, IT systems and a simulator.
Siemens S7
Reads data blocks, inputs, outputs and markers by address, and structures defined on the PLC. Read and write.
OPC UA
Reads the nodes of an OPC UA server at regular intervals or by subscription, when a value changes. Read and write.
Modbus TCP, SEW-Eurodrive and simulator
Registers and coils of PLCs, meters and instruments on TCP networks; the data SEW-Eurodrive drives send to the node over HTTP; test signals generated on the node, to build dashboards and alarms before the line is connected.
IT systems
New rows of a SQL Server table, a Prometheus server or its exporters, and queries to REST/HTTP services and MongoDB, PostgreSQL, MySQL and Oracle databases. Offered with Muvia Industrial or with the Gateway dati.
From PLC to tag, in three steps
- 01
Pick the driver
In Node configuration you add a driver to the node and choose the protocol.
- 02
Name the variables
Addresses or nodes to read, each with its tag name. They can be declared before the machine is even installed.
- 03
The data flows
The configuration reaches the node and values start flowing to Muvia.
In detail
- Siemens S7
- Read and write
- OPC UA
- Read and write; at intervals or by subscription
- Modbus TCP
- Read; TCP networks only
- SQL Server
- Reads the new rows of a table
- SEW-Eurodrive
- Receives over HTTP the data the drives send (SEW IoT Suite)
- Simulator
- Test signals generated on the node
- Prometheus
- A Prometheus server or its exporters' /metrics page
- Queries to IT systems
- REST/HTTP services and MongoDB, PostgreSQL, MySQL and Oracle databases
- Adding a driver
- In two steps: first the type, from cards grouped by family, then what it connects to
- Tags
- A tag can be renamed while its measures and readers follow the new name; the tag grid sets the unit the measures are read in
Frequently asked questions
Many controllers already expose an OPC UA server or a Modbus TCP interface. Before you start, ask an engineer to confirm the right route for your machine.
With Siemens S7 and OPC UA, yes. A write starts from a flow; in trial mode the flow really runs but the command is recorded instead of sent, so you see what it would do without touching the machine.
No: Modbus TCP only, over TCP networks.
Yes: the node reads SQL Server tables and a Prometheus server, and queries REST/HTTP services and MongoDB, PostgreSQL, MySQL and Oracle databases. These drivers come with Muvia Industrial or with the Gateway dati.
Tell us which machines you run. We'll tell you how to read them.
PLC brand, protocol, how the floor is connected: with those three answers, in a demo with one of our engineers, we show you how Muvia Industrial puts line data next to the rest of the business.